PG&E all-day training class for Universal Translator 3 April 23, 2015 San Francisco, CA Time in Video Presenter / Topic ------------------------------------------------------- Ryan Stroupe (r2s2@pge.com) 00:00:00 Introductions ------------------------------------------------------- Reinhard Seidl (rseidl@taylor-engineering.com) 00:07:55 Introduction, initial problems with slide show 00:09:30 Introduction of speakers 00:12:30 UT3 history and new features 00:22:40 Agenda for the day ------------------------------------------------------- Ryan Stroupe (r2s2@pge.com) 00:23:25 Downloading/Importing class materials/files Pre-loaded projects for use in class 00:26:45 Import data (simple file import) 00:35:15 Create simple Chart 00:41:50 Searching for channel names 00:44:15 Multiple Y-axes 00:48:15 Multiple Graph Panes 00:52:30 Zoom 00:52:55 Time Correction 00:56:30 Time Stamp Synchronization, and time step adjustment 01:00:40 Multiple channel time stamp changes 01:03:00 Data Export ------------------------------------------------------- Andrew Krioukov (andrew@buildingrobotics.com) 01:13:00 Introduction (Reinhard Seidl) importance of Data collection and associated problems 01:16:20 Andrew start - Background on Building Robotics 01:19:45 Login to PEC Trendr Box and connection to Building Management system 01:37:00 Graph and Economizer Analysis with imported data 01:42:45 Using Trendr web interface for viewing data ------------------------------------------------------- Ryan Stroupe (r2s2@pge.com) 02:03:00 Problem with data export for certain Windows versions, and workaround ------------------------------------------------------- Reinhard Seidl (rseidl@taylor-engineering.com) 02:04:30 Economizer Analysis 02:07:45 Data Preview in simple graph 02:08:45 Create Analysis Module 02:10:00 Subfolder creation and data separation (manual) 02:11:50 Channel assignments in analysis module 02:12:50 Exampples of real world economizers on small tonnage package units 02:16:00 Problems with field verification of airflows and reason for economizer module 02:25:30 Interpreting results 02:32:00 Selecting channels that represent Unit status 02:34:30 Filtering data for unit status 02:39:30 Viewing Filtered analysis 02:46:15 Adjusting fixed return air temperature 02:48:45 Import multiple examples from class handout and interpret results 02:52:30 Unit with good performance 02:56:00 Effect of supply air temperature reset 02:59:00 Unit with good performance 02:59:45 Economizer damper stuck closed 03:00:30 Economizer damper stuck open 03:01:20 Economizer damper stuck open 03:07:00 Data Import Errors 03:27:00 SQL data import prototype 03:31:00 Effect of heating coil on Economizer Analysis ------------------------------------------------------- Dove Feng (dfeng@taylor-engineering.com) 03:51:45 M&V Analysis - Introduction and background of M&V type measurements and usage for savings calculations 04:02:15 Import data for class exercise 04:07:00 Preview data with simple charts 04:08:30 Selecting independent variable for regression 04:16:30 Using a schedule filter to check data patterns 04:36:00 Create new M&V Module 04:37:35 Using simple scatter chart for comparing baseline and post-retrofit data 04:41:40 Building the baseline model 05:00:30 Predicted and Modeled data - explanation of the meaning of channel types 05:02:00 Post-implementation data and extrapolation of data from a representative time period 05:04:15 Open full example model 05:11:15 Finished baseline composite model 05:12:00 Post-implementation model ------------------------------------------------------- Ryan Stroupe (r2s2@pge.com) 05:49:45 Lighting Controls (Example4-light) 05:51:30 Charting input 05:53:30 Changing time interval for data sampling 05:55:10 Change to COV (change of value) type from time series 05:57:00 Schedule Filter for lighting 05:59:30 Create Analysis 06:03:40 Interpret results (reg.desk) 06:14:20 Mens room analysis ------------------------------------------------------- Reinhard Seidl(rseidl@taylor-engineering.com) 06:20:30 Setpoint Analysis. Data Import 06:26:00 Categorize data 06:28:00 New Folders: split into buildings 06:31:30 New Folders: split up VAV's 06:36:40 New Analysis 06:41:15 Graph to check data 06:43:30 Open pre-configured project file 06:45:00 Graph to check data 06:46:00 New Analysis (ABSOLUTE VALUES, room temps) 06:49:00 Results interpretation, copy to excel and filter 06:53:00 Erroneous Sensor data 06:53:50 Template graph to check results 06:57:30 Checking the worst performers (hottest zone) 07:00:30 Checking high temperature without alarm (unocc) 07:04:00 Filtering a template graph 07:05:15 Filtering the analysis 07:07:15 Checking the worst performers in filtered result (hottest zone) 07:08:30 New Analysis (RELATIVE VALUES, airflows) 07:11:30 Checking results in graphs (scatter) 07:14:00 Comparing absolute and relative results ------------------------------------------------------- Various Speakers 07:15:00 Q&A